China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

TesterMeter-TQ-J4-Overhead High Voltage live line Fault Indicator,Overhead cable type grounding short circuit addresser

TesterMeter-TQ-J4-Overhead High Voltage live line Fault Indicator,Overhead cable type grounding short circuit addresser

2023-07-05 21:34:13  

TQ-J4-Overhead High Voltage live line Fault Indicator,Overhead cable type grounding short circuit addresser

  • Main Feature :
  • Serial No. :
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

MAIN FEATURES

1,Fault indication: During normal operation, the window is displayed in white; when a short circuit or ground fault occurs, the window is displayed in red , flipping cards during the day and glowing at night .

2, On-line operation: Directly installed on the line, maintenance-free.
3,Strong anti-interference: The signal is not affected by lines, excitation inrush current, high-order harmonics, current fluctuations, and cable distributed capacitance bypass.
4,Auto reset: After the action is flipped, it will reset automatically according to the set time or reset by electric shock. (Reduce labor of maintenance personnel)
5,On-line loading and unloading: live loading and unloading is extremely simple and does not affect the line operation.

Working Principle

Short circuit fault criterion of overhead line

( l ) I t ≥ 80A I t is the starting value of the sudden change current (special current can be customized)

( 2 ) I 0.5I 0              I is the current change rate, and I 0 is the line current before the short circuit

( 3 ) I = 0 I is the current after line fault

( 4 ) 0.02s ≤△ T 3s    T is the current mutation time

图片关键词


Ground fault criterion of overhead line

The principle of short-circuit fault in the four- grounding short -circuit is the same as that of TQ-J2 . The principle of grounding detection: sampling the first half-wave of the capacitor current at the moment of grounding and the first half-wave of the voltage at the moment of grounding, compare their phases, when sampling the capacitance at the moment of grounding If the current suddenly changes and is larger than a certain value, and is in phase with the first half-wave of the voltage at the moment of grounding, and at the same time the voltage of the wire to the ground decreases, it is judged that the line is grounded, otherwise the line is not grounded. Schematic diagram of fault indication for judging grounding:

图片关键词

By the indicator of 3 , 6 and 9 of phase C of 2# line turning the red card to display and the indicator of 12 is still white, it can be judged that the ground fault at point D has occurred .

TECHNICAL SPECIFICATION

Applicable voltage level:    Applicable voltage level:    110KV U 6KV(Can Customize:400V )
Applicable wire current: I 1000A
Applicable wire diameter:  25mm2 ≤ d 500mm2(overhead bare wire, overhead insulated wire )
Action response time:  0.02S T 3 S
Static power consumption:     ≤0.5μw ( basically        zero power consumption after product action , to ensure product service life )
Action reset time:    6 , 12 , 18 , 24 hours optional (labor saving)
Ambient temperature: - 35 ℃≤ T +75
Ambient humidity: < 100%
Number of actions:        ≥6000 times
Product weight:   ≤ 400g
Service life:        ≥8 years
Protection level:    IP67
Earthquake resistance: the ground horizontal acceleration is 0.3g , the vertical acceleration is 0.15g  , and the safety factor of 3 sine waves is 1.67 at the same time.
Dirty level: Level IV
Withstand short-circuit current capability: 40KA/2s
Display mode:Flop and flash display can be observed within a 360-degree range
Working power: 3.3V/2.8ah
Altitude:  < 3km


Telephone
Email
Map
QQ Chat