China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

TesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm
TesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm
TesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm
TesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm
TesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm
TesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm
TesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm
TesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm

TesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm

2023-07-20 15:35:31  

The alarm is installed on the grounding clamp or insulating rod. When the cable or equipment is charged, the alarm triggers the alarm function and sends out an audible and visual alarm to remind the operator to pay attention to safety, avoid electric shock accidents, and provide safer protection for the operator.

  • Main Feature : Alarm voltage range: 40V ~ 10kV Electricity test method: non-contact Alarm mode: sound and light alarm Working frequency: 50Hz/60Hz Power supply: lithium battery DC 7.4V 600mAh Protection class: IP65
  • Serial No. :

Contact Us for QuotationEmail:464560351@qq.comWhatsapp: +8618620373879

PRODUCT INTRODUCTION

TheTesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm provides a safe, practical and convenient new near-electric alarm device for electric workers. When electric power workers perform power outage maintenance on power cables and equipment, due to induced voltage or other reasons, in order to ensure the safety of workers, they need to use grounding clamps to ground the cables or equipment. The alarm is installed on the grounding clamp or insulating rod. When the cable or equipment is charged, the alarm triggers the alarm function and sends out an audible and visual alarm to remind the operator to pay attention to safety, avoid electric shock accidents, and provide safer protection for the operator.

The TesterMeter-ETCR1850 Grounding Lead& Clip Device Approach Electrical Alarm adopts non-contact sensing technology to sense the electric field in the air in all directions, and the alarm is accurate. The power consumption of the alarm is very small, and the standby time is as long as 6 months. There are many ways to install the alarm, and it is very convenient to install and evacuate. The alarm is sturdy and durable, and the protection level is IP65. This product can also be used for line fault detection and electroscope use.

Features

There are many ways to install the alarm, and it is very convenient to install and evacuate.

Using non-contact sensing technology, the alarm is accurate, the power consumption of the alarm is very small, and the standby time is as long as 6 months.Omnidirectional induction voltage source, automatic trigger detection mode, sound and light alarm mode, to ensure the safety of workers near electricity.

Technical parameter

1.  Alarm distance

Voltage level

40V

110V

220V

600V

1kV

10kV

Alarm distance

4cm

10cm

15cm

25cm

35cm

200cm

2.  Technical specifications

Function

near call alarm

power supply

Lithium battery DC 7.4V 600mAh

Alarm voltage range

40V~10kV

working frequency

50Hz/60Hz

Electricity test method

Contactless

detection mode

automatic trigger

operating hours

Continuous work (sound and light alarm): about 48 hours

Standby time: 6 months

Alarm method

Indicator light: keep flashing

Buzzer: continuous beep-beep-beep sound

weight

Alarm: about 125g (including battery); total mass: about 310g (including accessories)

Dimensions

Length X width X thickness: 80mmX77mmX57mm

degree of protection

IP65

Working temperature and humidity

-10℃~40℃; below 80%rh

storage temperature and humidity

-10℃~60℃; below 70%rh