China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

TesterMeter-MIX6071-M Laser Dust Sensor

TesterMeter-MIX6071-M Laser Dust Sensor

2023-07-06 16:07:08  

Target Gas: To detect PM2.5 and PM10.0 Range :0-1000ug/m³ Application: Air purifier,Air Quality Monitor,HAVC refrigeration

  • Main Feature :
  • Serial No. :
Contact Us for QuotationEmail:464560351@qq.comWhatsapp: +8618620373879

Principle Introduction

TesterMeter-MIX6071-M laser dust sensor is a NDIR dust sensor, which can detect the mass concentration (BSP) of PM2.5, PM10 and large particles of dust in the air.

It is used for the detection of small particles in the air indoors and outdoors. The sensor contains a laser and light. The electric receiving device uses the principle of light scattering to scatter light on the dust particles through the laser. And the photoelectric converter is converted into an electrical signal, and the particle concentration software algorithm calculates the particle concentration. The mass concentration of the particulate matter.

Features

* NDIR detection principle

* To detect PM2.5 and PM10.0

* Response time:<5s                                       

* Power current:≤80mA

* Output signal: UART/TTL matches with RoHS and REACH  

 

Diversity Features:

• Real-time detection output

• Accurate and reliable data   

• The smallest resolution particle size is 0.3 microns

• With anti-interference ability

• Standard TTL serial data output

• Small size and easy to install

Application

* Air purifier

* Air Quality Monitor

* HAVC refrigeration

* Environment Monitoring

Technical Parameters

ItemSpecification
Measurement Range of Particle MatterPM2.5,PM10
Effective Measurement Range of Particle Matter Mass Concentration0-1000ug/m³
PM2.5 and detection range is 0~600 ug/m³≥100 ug/ m³:±10%
<100 ug/ m³:±10 ug/ m³
PM10.0 and detection range is 0~1000 ug/m³≥100 ug/ m³:±25%
<100 ug/ m³:±25 ug/ m³
Concentration level of large particles
0~100 levels
0~20Lev: ±5Lev;
20~100 Lev: ±25%
Note: The range of concentration level (Lev) is 0-100. The particle mass concentration PM <6ug/m³
corresponds to level 0, 6 ≤ PM <12ug/m³
corresponds to level 1, and so on, 600ug/m³ and above corresponds to level 100

MIX6071-M Specifications:

ItemSpecification
Data InterfaceUART TTL ,  9600 bps
Power VoltageDC 5±0.5V, Ripple wave<50mV
 
Working Condition
Temperature.: -15℃~60℃
Humidity: 0-95%RH(non-condensing)
 
Storage Condition
Temperature:-30℃~70℃
Humidity:0-95%RH(non condensing)
Weight25g
Product Dimension48mm*40mm*13.5mm
 
Average No Fault Time
≥40000H
Intermittent mode: depending on intermittent work