China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

TesterMeter-DS400FKC-(50A-400A) (ACDC) φ12mm Open-loop Hall current Sensor

TesterMeter-DS400FKC-(50A-400A) (ACDC) φ12mm Open-loop Hall current Sensor

2023-07-07 08:54:31  

(50A-400A) (ACDC) φ12mm

  • Main Feature : Name:Xtester-DS400FKC-(50A-400A) (ACDC) φ12mm Open-loop Hall current Sensor
  • Serial No. :
Contact Us for QuotationEmail:464560351@qq.com Whatsapp: +8618620373879

TesterMeter-DS400FKC-50A-400A (ACDC) φ12mm Open-loop Hall current Sensor

The current sensor based on the Hall Effect open-loop principle can measure DC, AC, pulse and various kinds of Irregular waveform current under electrical isolation conditions.

Click to download:  TesterMeter-DS400FKC-50A-400A (ACDC) φ12mm Open-loop Hall current Sensor

TECHNICIAL SPECIFICATION

Model Number

              TesterMeter-DS400FKC-(50A-400A) (AC/DC)

Jaw Size

φ12mm

Rated input Current (IPN)

50

100

150

200

300

400

A

Primary Current Measure range(IP)

0~±100

0~±200

0~±400

0~±600

0~±800

0~±900

A

Rated output voltage of secondary side

4±1%

V

Power Supply Voltage (VCC)

±12-±15(±5%)

V

Current consumption

VC=±15V         <25

mA

Galvanic isolation (Vd)

3KV /50Hz/1min


Linearity (εL)

<1

%FS

Accuracy X

TA =25℃                                  ±1

%

Offset Voltage V0

TA=25℃                     <±25

mV

Hysteresis offset Current IOM

IPN→0                       <±25

mV

Offset Voltage drift VOT

IP=0  TA=-25~+85℃               <±1

mV /℃

Response time Tr

≤7

μs

Operating temperature TA

-25~+85

Storage temperature TS

-40~+100

Frequency bandwidth(-3dB)

DC-20

KHZ

Load resistance RL

≥10k

Ω

Weight

43

g

Matters needing attention:

  • The wrong connection may cause sensor damage. After the sensor is energized, the same phase voltage is measured at the output when the current wire cross the sensor center according the direction arrow indicating label.

  • The output range of the sensor can be adjusted according to the user's needs.

  • Vout is positive when the Ip flows in the direction of the arrow.

Hall Current Sensor  Selection Guide

Model NumberRangeDiameterOutputPower Supply

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter--DRB1

50,100,200,300A20mm(Close Loop)50,100,100,150mADC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter--DRK1D

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)2.5±1.25V  ( ±1%)DC  +5V (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter--DRK1

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)4or5,4-20 mA,0-20 mA±1%DC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter--DRK1AC

50,100,200,300,400,500A(AC)21mm(Open Loop)4or5,4-20 mA,0-20 mA±1%DC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRK3D

50,100,200,300,400,500A(AC/DC)10*20mm(Open Loop)2.5V±1.25V    ±1%DC  +5V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRK3

50,100,200,300,400,500A(AC/DC)10*20mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRK5

300,500,600,800,1000,1500A(AC/DC)37*42.5mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRKH1

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRKH2

300,400,600,800,1000,2000A(AC/DC)40.5mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRKH4

600,800,1000,2000,2500,3000A(AC/DC)80mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DRKH5

600,1000,2000,3000,5000A(AC/DC)42*400mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter--DS10000LC

1000,3000,5000,8000A,10000A(AC/DC)140*36mm(Open Loop)4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DS8000DKL

10000,20000,30000,40000,60000A,80000A(AC/DC)120mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

TesterMeter- DS4000IAX

500,800,1000,1500,2500A,4000A(AC/DC)64*21mm(Open Loop)4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS1500DFA

200,400,600,800,1000A,1500A(AC/DC)
40*30.2mm(Open Loop)
4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS20000IC

5000,7500,10000,15000,20000A,(AC/DC)210*100mm(Close Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS10000IB

2000,3000,5000,8000,10000A,(AC/DC)140*50mm(Close Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS6000FKF

300,600,1000,2000,4000,6000A,(AC/DC)φ62mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS5000LA

600,1000,2000,3000,5000A,(AC/DC)104*36mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS5000LAA

500,1000,2000,3000,5000A,(AC/DC)102*38mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS2500LF2

500,1000,1500,2000,2500A,(AC/DC)85*27mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS2000L

300,500,800,1000,2000A,(AC/DC)64*16mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS2000GA

400,500,800,1000,2000A,(AC/DC)51*13mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS2000FB

500,800,1000,1500.2000A,(AC/DC)φ60.5mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS1000T

100,200,300,400,500,600,1000A,(AC/DC)φ32mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS1000FD

200,400,700,1000A,(AC/DC)φ17.5mm4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

TesterMeter- DS1000CF

200,400,600,800,1000A,(AC/DC)40.5*20.5mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS800FKH.80.jpg

TesterMeter- DS800FKH

100,200,300,500,800A,(AC/DC)φ35mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS600P.80.jpg

TesterMeter- DS600P

50,100,200,300,400,500,600A,(AC/DC)26*12mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-DS600F2.80.jpg

TesterMeter- DS600F2

100,200,300,400,500,600A,(AC/DC)φ28mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS600C.80.jpg

TesterMeter- DS600C

50,100,200,300,400,500,600A,(AC/DC)20.5*10.2mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS400FKC.80.jpg

TesterMeter- DS400FKC

50,100,150,200,300,400A,(AC/DC)φ12mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS040H.80.jpg

TesterMeter- DS040H

10,20,30,40A(AC/DC)φ5mm1±1%DC  ±12V- ±15V  (±5%)

MEWOI-DS2000DKO.80.jpg

TesterMeter-DS2000DKO

500,1000,5000,8000

12000,20000(AC/DC)

φ80mm4or5±1%DC  ±12V- ±15V  (±5%)


Telephone
Email
Map
QQ Chat